Vsh1230 fire extinguishing system with 3m novec 1230 fire. A brief history of cleaning solvents, comparison and why the 3m novec hfe engineered fluids solvent is the best solvent for your needs. It was developed to implement ultrasonic cleaning operations. Compare its properties with those of other chemical extinguishing agents see chart. Heat transfer properties can be enhanced by adding certain liquids having better thermal properties, to the existing heat transfer fluids. Additional information 3m novec 7100 is a proprietary hydrofluoroether from 3m.
Key properties novec insulating gas novec engineered fluids selection criteria 4710 5110 7000 649 7100 7200 7300 7500 7700. Contact with the eyes during product use is not expected to result in significant irritation. Novec 1230 fluid does not deplete ozone odp 0 and has a global warming potential of 1 over 80 years, equivalent to that of carbon dioxide. Identification of the material and supplier product name novec 1230 other names none recommended use fire protection agent for total flooding of rooms containing electrical equipment such as computer rooms as well as flammable. Novec will not call, text or email you to demand personal information like your credit card or bank account number, and we will not demand immediate payment with a prepaid debit card or other gift cards. Novec 1230 fluid systems allow for more efficient use of space, requiring about the same number of cylinders as conventional halocarbon agents. Some of this discrepancy can be related to the uncertainty in hfe fluid thermal properties 33. Engineered fluids and 3m fluorinert electronic liquids have unique properties including. Studies conducted on 3m novec 1230 fire protection fluid have determined the atmospheric loss rates via these removal mechanisms and the effect on the atmospheric lifetime of this compound. Not only does novec 1230 fluid meet todays regulations but it meets those of the foreseeable future.
These highperforming, fluid based products are designed to protect, clean, cool and enable new electronics products and processes. Why would i choose a novec fluid over a fluorinert fluid. If 3m novec 1230 fire protection fluid is banned from or restricted in use as a fire protection agent within 20 years after installation due to its environmental properties, well refund the purchase price of the fluid. It is nonconductive in both its liquid and gaseous state.
Fill manual for 3m novec 1230 fire protection fluid. Properties description 3m novec 1230 fire protection fluid features 2 novec 1230 safety and use concentration comparison properties halon 1 hfc227ea novec 1230 inert gas co 2 novec 1230. It is electrically nonconducting in both the liquid and gaseous state. The federal state of the government department of allrussian research institute for fire protection fgu vniipo of emercom of russia held tests to produce measurements of the minimal fire protection. However, the hfe7200 chf values were not predicted as well. Our line of 3m novec engineered fluids offer properties that make them ideal for immersion cooling, both in singlephase and twophase operation. Novec 1230 fluid offers a unique combination of safety, low environmental impact and extinguishing performance, making it the first chemical halon replacement to offer a viable, longterm, sustainable technology for special hazards fire protection. Protection fluid also known as fk5112, 3m novec 1230 fire protection fluid, c 6fketone produced by 3m.
Environmental novec properties sf 6 so 2 hfc4a 612 agent. Ebullient cooling of integrated circuits by novec fluids. Advantages of a liquid over a gas the following graph displays the unique properties that differentiate novec 1230. Novec 7100, methoxynonafluorobutane c4f9och3 is a proprietary clear, colourless and odourless liquid designed to replace the existing solvents.
Novec 1230 fluid is a highly efficient fire extinguishant that can be used for both streaming and flooding applications. Environmental properties of 3m novec 1230 3m novec 1230. The red curve is the maximum temperature curve, and the blue curve is the melting line if one is available for the fluid. Its physical properties are compared with several other. Novec 649 fluid is an effective heat transfer fluid with a boiling point of 49c. The company novec reserves the right to designate and or approve the location of the metering. Fire protection concentration of 3m novec 1230 3m novec. It is the basis for a large number of formulations. Novec engineered fluids excel as a cleaning solvent, with products available with a range of cleaning strengths, excellent materials compatibility and properties that make them suitable for many applications without the detrimental health or environmental effects common to trichloroethylene tce, npropyl bromide npb or other common cleaners. Physical properties novec 1230 fluid is applied as a gas, but is liquid at room temperature.
Personal safety life safety is a critical issue when selecting a special hazards fire suppression product. Milbrath 3m industrial chemicals, emmd international conference of sf6 and the. Generation novec will require additional detailed information pe rtaining to proposed generation. As highlyfluorinated compounds, novec fluids are ideal for clean. Environm ental precautions a void release to the environment. Its physical properties are compared with several other ods replacement fluid candidates in table 1. Novec engineered fluids are dielectric and nonflammable, offer a variety of operating temperature ranges and are lowmaintenance, lowmess alternatives to traditional cooling fluids such as water, water glycol or oils used for heat transfer. Safety data sheet 3m novec 1230 fire extinguishing agent.
Additionally, its liquid nature allows novec 1230 fluid to be easily transported in bulk, even by air. This table pulls together the three most important environmental attributes and puts them on one graph. Global warming potential gwp a parameter that provides a relative measure of the. Crucially, gl1230 fire extinguishing systems are designed specifically for novec 1230, the efficacy of which has been demonstrated by independently. How do i select a fluid for a particular application. Over a wide range of temperatures, a high boiling material like novec 1230 fluid, when superpressurized with nitrogen. This hydrofluoroether is a clear, colorless and lowodor fluid intended to replace ozonedepleting substances odss and compounds with high global warming potential gwp in many applications. We develop 3m novec engineered fluids with intention, to find solutions that clean, cool, coat and protect with a high level of performance and a large margin of safety while helping minimise the environmental impact on the world we live in. Novec fluids exhibit an optimized balance of performance, health, safety and environmental properties. In this figure, we start off with a state point given by t,p and then we calculate each of the other possible output pairs in turn, and then try.
Over a wide range of temperatures, a high boiling material like novec 1230. Typical applications novec 649 fluid is an effective heat transfer fluid with a boiling point of 49. The globally harmonized system of classification and labeling of chemicals ghs classifies this chemical as h412 harmful to aquatic life with long lasting effects. Novec 7100 engineered fluid is a proprietary methoxynonafluorobutane from 3m. Download the twophase immersion infographic pdf, 3.
Depletion potential odp for novec 1230 fluid is zero, meaning it has no effect on stratospheric ozone. Novec 1230 fire protection fluid has a boiling point of 49c 121 f. The following figure shows all the flash routines that are available for this fluid. Novec 1230 fluid has the largest margin of safety for use in occupied spaces. How do novec hfe fluids differ from fluorinert fluids. It can be shipped safely and effectively, without any restrictions, by air at a moments notice in bulk quantities.
Novec 1230 fluid is a highly fluorinated ketone containing no chlorine or bromine. Novec 7700 fluid shares many of the inerting and dielectric properties of perfluorocarbons pfcs and perfluoropolyethers pfpes, and is a viable option for. By joining the load management program, you can help your coop hold down the cost of providing power. The breakdown voltage of novec 1230 fluid vapor under saturated conditions at 1 atm, 21. It is a clear, colorless, low odor, liquid that is superpressurized with nitrogen and stored in highpressure cylinders as part of a sapphire suppression system. It makes good business sense to use novec 1230 fluid because it is a sustainable, longterm technology. The unique properties of 3m novec engineered fluids can be applied in a variety of ways to solve customer challenges in thermal management. Novec tm 7100 features used for all industries, novec 7100 is a fluid specially developed to clean, degrease, rinse and dry all kind of materials. One such challenge is the complexity of applying directtochip d2c water cooling, due to the risk of leaks and the difficulty of cooling a series of processors in the same circuit. Energy use and costs can be slashed by up to 97% while shrinking data center size and enabling optimal performance of server hardware while helping reduce environmental impacts. Ods replacement fluid candidates in tables 1 and 2. Novec electronic coating egc1700 3m novec electronic coating egc1700 is a clear, low viscosity solution of a. We intentionally develop products to help you solve your specific challenges and change the world for the better for your customers, your workers and future generations.
If thermal decomposition occurs, wear supplied air respiratory protection. The globally harmonized system of classification and labeling of chemicals ghs classifies this chemical as h412. Novec 1230 fluid is a liquid with a low vapor pressure at room temperature, which optimizes agent delivery to the seat of the fire, even in difficult conditions. With no residue left after a discharge, a system using 3m novec 1230 fluid is the optimal solution for minimizing downtime and protecting people, processes and irreplaceable assets. Our line of 3m novec engineered fluids offer properties that make them ideal for. Used for all industries, novec 7200 is a fluid specially developed to clean.
The company must approve all metering arrangements. Novec 7600 fluid shares many of the inertness and dielectric properties of perfluorocarbons pfcs and perfluoropolyethers pfpes, and is a viable option for replacing them in a wide. In the shop, novec 1230 fluid is easier to use than pressurized gas. Protect valuable equipment, people and assets with a clean agent fire suppression system using 3m novec 1230 fire protection fluid. Dec 12, 2016 the company novec reserves the right to designate and or approve the location of the metering and current transformer ct equipment. Properties analyzer is purportedly capable of measuring fluids with thermal. Fluorochemicals in heat transfer applications questions not answered herein may be directed to the 3m technical service hotline at 8008335045. The components of novec 7100 fluid have been nominated to chinas draft chemical inventory. A gas has no definite volume, and it forms an atmosphere when it is not confined. It is stored as a pressurized liquid and injected into a room, area, or compartment that has the structural integrity to retain the. A gas is free to expand until it encounters confining walls. By reducing the amount of power customers use especially during peak times novec can reduce the amount of power it purchases each year by millions of dollars. The customer must notify novec prior to the actual connection of any future load as required by. Novec engineered fluids are specifically designed for heat transfer, providing efficient.
Other novec hydrofluoroethers, azeotropics or mixtures formulation boiling temperature application novec 7100 methoxynonafluorobutane 61c. Novec 1230 fluid, delivered by gl1230 fixed systems from gielle, meets this demanding profile, precisely it complies with all statutory requirements, both current and anticipated. From fire protection fluid to aerosol cleaners to coatings for electronics. Novec 7500 fluid shares many of the inertness and dielectric properties of perfluorocarbons pfcs and perfluoropolyethers pfpes, and is a viable option for. Heat transfer novec fluids selection guide pg 1 3m. Salt water mist according to astm b11709 visual inspection after 48 hours exposure novec 2702 novec 1700 novec 2702 gives a better protection. This hightech fluid has no odp, its thermal and chemical stability, its non flammability and its very low toxicity provide the best compromise for the safety in use and the environment. And with their excellent materials compatibility, youll have the formulating freedom you need to create the perfect mix. The breakdown voltage of novec 1230 vapours in saturation. Identification product name 3m novec 1230 fire extinguishing agent, pressurized and nonpressurized recommended use of the chemical and restrictions on use fire extinguishing agentidentified uses.
1015 491 284 799 1584 1009 1152 38 1343 1067 1148 1321 1294 1532 931 30 968 1036 1275 984 279 1633 20 1212 739 1629 1478 899 1334 170 21 950 599 1167 686 895